现货斯坦福DS345 任意波形信号发生器 30MHz
作者:2011/1/8 5:24:57

中赛仪器库存大量各种高频仪器现货特价出售中--本公司长期现金大量高价回收各种高频仪器;如-网络分析仪-视/ 音频分析仪-信号发生器-频谱分析仪-手机综合测试仪 阻抗分析仪 LCR电桥 示波器 ******测试仪静电放电发生器等等…..仪器联糸人;张生 13556784911/18922936706电话;0769-33355531传真; 0769-23362124
选用二手测量仪器的优势是:
1、与新购仪器几个月的供货期相比,购买二手仪器的供货期要短的多。在时间就是市场的今天,优势无疑是最为明显的。
2、二手仪器的价格便宜,基本为新购仪器价格的20%~50%。在电子技术迅速发展的今天,仪器的更新也在加快,投资越少则风险越小。
3、为了让您放心地使用我们提供的二手仪器,我们销售的二手仪器可以做到:
1、保修半年至一年不等。
2、可以根据您的要求,将仪器送至国家级计量测试单位进行校准。
现货斯坦福DS345 任意波形信号发生器 30MHz
Function Generator
DS345 — Function & arbitrary waveform generator
DS345 任意波形信号发生器


Specifications
 

Frequency Range
 

 
 

Max. Frequency
 

Resolution
 

Sine
 

30.2 MHz
 

1 ?Hz
 

Square
 

30.2 MHz
 

1 ?Hz
 

Ramp
 

100 kHz
 

1 ?Hz
 

Triangle
 

100 kHz
 

1 ?Hz
 

Noise
 

10 MHz
 

(Gaussian weighting)
 

Arbitrary
 

10 MHz
 

40 MHz/n (sample rate)
 

Output
 

Source impedance
 

50 Ω
 

Grounding
 

Output may float up to ±40 V (AC + DC) relative to earth ground.
 

Amplitude
 

Range
 

0.01 to 10 Vpp (50 Ω), 20 Vpp (Hi-Z)
 

Resolution
 

3 digits (DC offset: 0 V)
 

Sine wave accuracy (0 V DC offset)
 

     5 to 10 Vpp
 

±0.2 dB (1 ?Hz to 20 MHz)
±0.3 dB (20 MHz to 30.2 MHz)
 

     0.01 to 5 Vpp
 

±0.4 dB(1 ?Hz to 20 MHz)
±0.5 dB (20 MHz to 30.2 MHz)
 

Square wave accuracy
 

 
 

     5 to 10 Vpp
 

±3 % (1 ?Hz to 100 kHz)
±6 % (100 kHz to 20 MHz)
±15 % (20 MHz to 30.2 MHz)
 

     0.01 to 5 Vpp
 

±5 % (1 ?Hz to 100 kHz)
±8 % (100 kHz to 20 MHz)
±18 % (20 MHz to 30.2 MHz)
 

Triangle, ramp, arbitrary accuracy
 

±3 % (>5 Vpp)
±5 % (<5 Vpp)
 

DC Offset
 

Range
 

±5 V (limited such that |VAC peak| + |VDC| < 5 V)
 

Resolution
 

3 digits (VAC = 0)
 

Accuracy
 

1.5 % of setting + 0.2 mV (DC only)
±0.8 mV to ±80 mV, depending on AC and DC settings
 

Sine Wave
 

Spurious components
 

<-55 dBc (non-harmonic)
 

Phase noise
 

<-50 dBc in a 30 kHz band centered on the carrier, exclusive of discrete spurious signals
 

Sub-harmonic
 

<-50 dBc
 

Harmonic distortion
 

Level
<-55 dBc
<-45 dBc
<-35 dBc
<-25 dBc
 

Frequency Range
DC to 100 kHz
0.1 to 1 MHz
1 to 10 MHz
10 to 30 MHz
 

Square Wave
 

Rise/fall time
 

<15 ns (10 to 90 %), at full output
 

Asymmetry
 

<1 % of period + 4 ns
 

Overshoot
 

<5 % of peak to peak amplitude at full output
 

Ramps, Triangle and Arbitrary Waveforms
 

Rise/fall time
 

45 ns (10 MHz Bessel filter)
 

Linearity
 

±0.5 % of full-scale output
 

Settling time
 

<1 ?s to settle within 0.1 % of final value at full output
 

Arbitrary Waveforms
 

Sample rate
 

40 MHz/N, N = 1 to 234-1
 

Memory length
 

8 to 16,300 points
 

Resolution
 

12 bits (0.025 % of full scale)
 

Phase
 

Range
 

±7199.999° with respect to arbitrary starting phase
 

Resolution
 

0.001°
 

Amplitude Modulation
 

Source
 

Internal (sine, square, triangle or ramp) or External
 

Depth
 

0 to 100 % AM or DSBSC
 

Rate
 

0.001 Hz to 10 kHz internal, 15 kHz max. external
 

Distortion
 

<-35 dB at 1 kHz, 80 % depth
 

DSB carrier
 

<-35 dB typ. at 1 kHz modulation rate (DSBSC)
 

External input
 

±5 V for 100 % modulation, 100 kΩ impedance, 15 kHz bandwidth
 

Frequency Modulation
 

Source
 

Internal (sine, square, triangle, ramp or arbitrary)
 

Rate
 

0.001 Hz to 10 kHz
 

Span
 

1 mHz to 30.2 MHz (100 kHz for triangle, ramp)
 

Phase Modulation
 

Source
 

Internal (sine, square, triangle, ramp)
 

Rate
 

0.001 Hz to 10 kHz
 

Span
 

±7199.999°
 

Frequency Sweep
 

Type
 

Linear or log, phase continuous
 

Waveform
 

Up, down, up-down, single sweep
 

Time
 

0.001 s to 1000 s
 

Span
 

1 mHz to 30.2 MHz (to 100 kHz for triangle, ramp)
 

Markers
 

Two markers may be set at any sweep point (TTL output)
 

Sweep output
 

0 to 10 V linear ramp signal, synchronized to sweep
 

Burst Modulation
 

Waveform
 

Any waveform except noise may be burst modulated
 

Frequency
 

Sine, square to 1 MHz
Triangle, ramp to 100 kHz
Arbitrary to 40 MHz sample rate
 

Count
 

1 to 30,000 cycles/burst (1 ?s to 500 s burst time limits)
 

Trigger Generator
 

Source
 

Single, Internal, External, Line
 

Rate (internal)
 

0.001 Hz to 10 kHz (2-digit resolution)
 

External trigger
 

Positive or negative edge, TTL
 

Output
 

TTL level
 

Standard Timebase
 

Accuracy
 

±5 ppm (20 °C to 30 °C)
 

Aging
 

5 ppm/year
 

Input
 

10 MHz/N ± 2 ppm (N = 1 to 8) 1 Vpp minimum input level
 

Output
 

10 MHz, >1 Vpp sine into 50 Ω
 

Optional Timebase
 

Type
 

Ovenized AT-cut oscillator
 

Stability
 

<0.01 ppm, 20 °C to 60 °C
 

Aging
 

<0.001 ppm/day
 

Allan variance (1 s)
 

<5 × 10-11
 

General
 

Interfaces
 

Optional RS-232 (300 to 19.2 kbaud, DCE) and GPIB with DOS based arbitrary waveform software (AWC). All instrument functions are controllable over the interfaces.
 

Non-volatile memory
 

Nine sets of instrument settings can be saved and recalled
 

Dimensions
 

8.5" × 3.5" × 13" (WHL)
 

Weight
 

10 lbs.
 

Power
 

50 W, 100/120/220/240 VAC, 50/60 Hz
 

Warranty
 

One year parts and labor on defects in materials and workmanship
 