IEC 60502 标准单芯电力电缆
IEC60502标准单芯电力电缆应用IEC60502标准电力单芯线缆的设计配电范围为1.8/3KV到26/35KV,频率为50Hz。主要应用于电力供应站,室内管道、室外,地下和海底水中,以及对行业,配电站,电力站线缆的安装。标准:IEC60502Part1(1.8/3KV)IEC60502Part2(3.6/6KV到18/30KV)结构:导体:平纹退火铜或铝导体,符合IEC602281类,2类。导体屏蔽:导体屏蔽层由非金属层,半导体复合挤压层牢固粘结绝缘层,排除所有缝隙。导体屏蔽层对于1.8/3KV到3.6/6KV范围内的PVC,EPR/HEPR绝缘的线缆不是必须的。绝缘:1.8/3KV及3.6/6KV电缆范围一般采用PVC,也可采用XLPE,EPR/HEPR绝缘。表1.XLPE或EPR/HEPR绝缘厚度标称截面积标称电压下的绝缘厚度1.8/3KV(UM=3.6KV)3.6/6KV(UM=7.2KV)6/10KV(UM=12KV)8.7/15KV(UM=17.5KV)12/20KV(UM=24KV)18/30KV(UM=36KV)21/35KV(UM=42KV)26/35KV(UM=42KV)MM2MMMMMMMMMMMMMMMMXLPE/EPRXLPEEPRXLPE/EPRXLPE/EPRXLPE/EPRXLPE/EPRXLPE/EPRXLPE/EPR非屏蔽屏蔽102.02.53.02.5------162.02.53.02.53.4-----252.02.53.02.53.44.5----352.02.53.02.53.44.55.5---50–1852.02.53.02.53.44.55.58.09.310.52402.02.63.02.63.44.55.58.09.310.53002.02.83.02.83.44.55.58.09.310.54002.03.03.03.03.44.55.58.09.310.5500-16002.2-2.83.23.23.23.44.55.58.09.310.5*3.6/6KV线缆PVC绝缘厚度是3.4mm(1-1600mmsq).绝缘屏蔽:挤压半导电交联复合层是应用在绝缘外层。半导体挤压层应该包括粘结的,或可剥离半导体复合层,进行焊接或终止去除能力。作为一个选项,一个半导电胶带可应用于对挤出半导电金属层为垫层。***小厚度为0.3毫米,***大为500欧姆的电阻率,在90℃的米屏蔽是紧密安装在绝缘排除所有空气空隙,可以很容易地在现场用手剥离。绝缘屏蔽层对于1.8/3KV到3.6/6KV范围内的PVC,EPR/HEPR绝缘的线缆不是必须的。屏蔽层可以包覆在半导体防水层的外围以做到纵向防水。金属层:金属层可以应用在单芯也可以应用在多芯外围。下面是我们可以提供几种金属层:1)金属屏蔽2)同心导体3)金属护套4)金属铠装金属屏蔽层包括铜带或者同心式铜丝或者铜丝和铜带的组合。金属层提供了一个接地故障电流路径,同心导体可以由绝缘覆盖,绝缘加屏蔽覆盖或内护套层。金属护套一般为铅或者铅合金的紧密无缝的管状物。金属铠装可以是扁平钢丝状铠装,圆形钢丝铠装和双层钢带铠装。表2.金属屏蔽***小截面积标称截面积***小屏蔽截面积铜丝屏蔽的直流电阻MM²MM²MMupto120161.06150-300250.72400-630350.51800-1000500.35分离式护套(铠装线缆):分离式护套包括一个挤压层,挤压层材料为PVC,PE或者LSZH,挤压层厚度一般为0.02Du+0.6mm,Du是一个根据护套等技术参数计算出来的直径。一般的分离式护套厚度大于1.2mm。分离式护套一般应用在铅护套的外层,普通的分离式护套厚度小于1.0mm。绕包垫层(铅护套铠装线缆):绕包垫层一般由纸带的浸渍/合成物组成,也可以是两层的复合,这种带由一种***的符合材料组成。厚度一般在1.5mm左右。铠装层(针对铠装线缆):铠装层一般为圆钢丝铠装,应用在分离式护套的外层。表3.圆钢丝铠装线缆直径铠装层下的虚拟直径铠装线缆直径MMMM><-100.810151.2515251.625352.035602.560-3.15外护套:外护套挤压层包含挤压热塑性复合物(PEV,PE或LSZH均可选),或弹性复合物(聚氯丁烯CSP或氯磺化聚乙烯)。通常的外护套厚度为0.035+D,D表示外护套的直径,单位为毫米。非铠装线缆和非铠装总护套线缆,金属层屏蔽或同心导体,外护套厚度应该小于1.4mm,同心导体总护套金属铠装线缆的外护套厚度应该大于1.8mm。物理特性:工作温度:可达70°C(PVC绝缘);可达90°C(XLPE或EPR绝缘)温度范围:-5°C(PVC护套);-20°C(PE护套)短路温度(短路时***长持续时间不超过5s):140-160°C(PVC护套);250°C(PE护套)弯曲半径:12xOD表4.常规/操作/测试:常规UO/U操作(UM)测试(RMS)1.8/3KV3.6KV6.5KV3.6/6KV7.2KV12.5KV6/10KV12KV21KV8.7/15KV17.5KV30.5KV12/20KV24KV42KV18/30KV36KV63KV21/35KV42KV73.5(53)*KV26/35KV42KV91(65)*KV*21/35KV和26/35kV工频耐压试验,可根据下列条件:2.5Uox30m或3.0Uox15m.括号中的数字实验条件为:3.0Uox1.5mins.单芯1.8/3KV(Um=3.6KV)电缆结构参数标称截面积非铠装线缆钢丝铠装绝缘标称厚度铜带厚度铜丝屏蔽面积标称护套厚度近似外径近似重量标称护垫厚度铠装厚度护套标称厚度近似外径近似重量CUALCUALMM2MMMMMM2MMMMKG/KMMMMMMMMMKG/KM102.00.1161.8132401801.21.61.818460400162.00.1161.8133002001.21.61.819530430252.00.1161.8154102501.21.61.820650500352.00.1161.8165103001.21.61.821780560502.00.1161.8176403501.21.61.822930640702.00.1161.8198504401.21.61.8241170750952.00.1161.82011305401.21.61.82614608701202.00.1161.82213706301.21.61.82717309901502.00.1251.82316507301.21.61.829203011101852.00.1251.82520108601.21.61.930243012802402.00.1251.827257010501.21.62.033304015303002.00.1251.829316012501.22.02.136376018604002.00.1351.933398015601.22.02.239466022305002.20.1352.135.5491019051.32.52.543593029306302.40.1352.239.7634024201.42.52.649737034308002.60.1502.344.5789029801.42.52.7529070423010002.80.1502.549.4989037001.52.52.956111004950*铜带复合物可以作为屏蔽层的可选项,屏蔽标称面积,以上表中数据作为参考电气性能参数标称截面积直流电阻CU/AL交流电阻CU/AL导体短路额定值CU/AL1SEC电容充电电流铜丝屏蔽短路额定值1SEC铜带屏蔽短路额定值1SEC电感阻抗电抗三叶形平坦,间隙三叶形平坦,间隙三叶形平坦,间隙CUALCUALMM2ΜΩ/MΜΩMKAPF/MMA/MKAKAΜΩ/MNH/MΜΩ/MΜΩ/M101830/30802330/39201.4/0.91820.272.60.21512013845582332384623323840161150/19101460/24202.2/1.42010.292.60.3140193362546146224111478242025727/1200927/15383.6/2.32220.322.60.31311853455359361544952155435524/868668/11135.0/3.22510.352.60.41221783275246791121695113150387/641494/8226.8/4.42810.392.60.411617231351451183452784470268/443343/5689.8/6.33410.452.60.511016530049536458338659795193/320248/41013.3/8.53970.502.60.5104160287485272427300446120153/253196/32517.2/11.04300.552.60.6104159283480225345257367150124/206159/26621.2/13.54640.594.30.610015628047519328722931318599.1/164128/21126.6/17.05130.654.30.79815427446516523720626724075.4/12598/16134.9/22.35730.704.30.99415026745914019118522630060.1/10080/13043.8/28.06520.724.31.09114726045512816317420340047.0/77.864/10257.3/36.67270.755.81.19014725344511314116418450036.6/60.551/8172.3/46.27540.795.81.28914524843510512415817163028.3/46.942/6491.2/58.37860.875.81.3861432454259711015116080022.1/36.735/55114.4/75.08460.918.21.48514224341592101147153100017.6/29.130/46143.0/94.09160.998.21.5831412394058895144148*对于EPR绝缘的电容和充电电流值,再次基础上乘以1.2。单芯3.6/6KV(Um=7.2KV)单芯6/10KV(Um=12KV)单芯8.7/15KV(Um=17.5KV)单芯12/20KV(Um=24KV)单芯18/30KV(Um=36KV)单芯21/35KV(Um=42KV)单芯26/35KV(Um=42KV)单芯额定电流1.8/3KV(Um=3.6KV)to26/35KV(Um=42KV))
上海特润系统控制有限公司
业务 QQ: 794031063