供应变压器保护用高压限流熔断器
◆型号说明Typeinstruction◆熔断器的选用ApplyingForappropriateFuses变压器容量KVATranstormercapacity变压器初级电压(相对相)Primaryvoltageofthetransformer(phasetophase)12KV15.5KV熔断器额定电流RatedCurrentoffuse-link2002020225252030031.52550050407356350◆订货号ordernumber额定电流ARatedCurrent熔断件订货号Fuse-linkOrderNumber底座订货号Fuse-baseOrderNumber20ZGR2-20ZGR2-D25ZGR2-2531.5ZGR2-31.540ZGR2-4050ZGR2-5063ZGR2-63◆概述GeneralZGR2(XRNT4)-15.5变压器保护用的高压限流熔断器(以下简称熔断器)适用于交流50Hz,额定电压15.5KV,额定电流至63A的高压户内电力系统,作为电力变压器的过载和短路保护。TypeZGR2(XRNT4)-15.5H.V.Current-limitingfuseforprotectionoftransformer(here-underfuse)isafullrangefuse,itisavailableforH.V.indoorelectricsystem,withratedvoltage15.5KV,ratedcurrentupto63A,50Hza.c..Itisusedforprotectingfromoverloadandshort-circuitforpowertransformer.◆标准Standard符合GB15166.2交流高压熔断器限流式熔断器AccordwithGB15166.2Alternating-currenthigh-voltagefusesCurrent-limitingfuse◆熔断器的结构Construction断器是由熔断件,手柄和支持件组成,熔断件的两端分别插入手柄中的接触柱内,并用紧定螺钉固定,插入支持件。Thefuseconsistsofafuse-link,afusecarrierandafuse-mount.Eachsideofthefuse-linkshouldbeinsertedintotheconnecting-cartridgeandfixedbyabolttightlythenputitintothefuse-mount.◆基本参数Basicparameters额定电压(KV)RatedVoltage最高电压(KV)MAX.Voltage15.517.2熔断器额定电流(A)Ratecurrentofthefuse63熔断件额定电流(A)Ratecurrentofthefuse-link20、25、31.5、40、50、63、80*、100*额定短路开断电流(KA)Ratebreakingcapacity50使用环境Operatingcondition空气,变压器油中Intheairandoiloftranstormer雷电冲击耐受电压分值KV对地75断口110注:*为双拼Note:*parrallelfuseapplication(ordertwofuses)◆外型及安装尺寸InstallationDimensios图1熔断件外形尺寸图2熔断器支持件的外形尺寸及安装尺寸熔断器安装与外形尺寸图2熔断器支持件的外形尺寸及安装尺寸熔断件安装熔断器的时间-电流特性TheTimecurrentCharacteristicOfTheFuse时间-电流特性曲线◆概述Genera□XRNT□(ZGR2)-40.5变压器保护用高压限流全范围熔断器,适用于交流50Hz,额定电压40.5KV的电力系统。作为电力变压器及其它电力设备的过载和短路保护。是电力系统中作为电力压器的过载和短路故障的保护元件。主要安装于美式箱变中,可与其它电器元件共箱。当电流超过规定值一定时间后,以它本身的热量使熔体熔化而开断电路的开关装置。◆基本参数Basicparameters额定电压KV熔断器额定电流A熔断器额定电流A熔断最大开断电流KA40.54020、25、31.5、4031.5◆型号说明Typeinstruction◆熔断器的结构Construction熔断器由熔断件,底座和载熔件(手柄)组成,结构为插入式。熔断件外形为圆柱形。它由玻纤环氧熔管、触头圆帽、熔体、云母骨架、石英砂组成。熔断件的两端分别插入载熔件的接触柱内,并用紧定螺钉固定与载熔件连为一体。底座端半圆凹槽内垫上O型密封圈,将安装熔断件的载熔件插入底座,旋上帽盖,插入及持件。熔断器的外形尺寸及安装尺寸熔断件的外形尺寸见图1。熔断器的安装尺寸和外形尺寸见图2。◆外型及安装尺寸InstallationDimensios图2熔断器的外形尺寸及安装尺寸◆支持件(底座)安装方法:1、卸下帽盖、手柄,再将将帽盖旋上支持件(防止支持件螺纹受损)。2、将密封圈套于支持件相应槽内,将支持件小端穿入箱体相应孔(用户根据箱体设计绝缘支架及附件,绝缘支架先行安装,以支撑支持件),支持件上四孔与螺栓相对应,旋紧四固定螺母。3、移动两可调绝缘契块到契块斜面与支持件面接触,旋紧契块固定螺栓。4、收紧绝缘扎带(或采用Φ4-Φ5U型金属线材)将支持件与绝缘支架固定,以防支持件受力损伤。◆型号说明Typeinstruction◆订货号Ordernumber额定电流ARatedcurrent熔断件订货号Fuse-linkOrdernumber底座订货号Fuse-baseOrdernumber6.3ZGR5-6.38ZGR5-810ZGR5-10ZGR5-D12.5ZGR5-12.516ZGR5-16◆熔断器的安装Installation1、底座的安装Fuse-base熔断器底座的安装示意图见图4,安装面板上开孔尺寸及4只M8螺栓定位尺寸见图2,4只M8螺栓是用来固定底座,油箱的密封性通过密封圈加以保证。InstallationofFuse-baseisshowninFin.4.ThesizeofopeningtheboreintheInstallationpanelandtheorientationsizeoffourboltsofM8areshowninFig,2.ThefourboltsofM8areusedtofixthebase.Sealwasherisusedtoassuresealcapabilitlyofoilbox.2、熔断件的安装Fuse-link熔断器叫熔断件被固定在手柄中,安装示意图见图5。熔断件安装时,熔断件端面的焊锡处尽可能避开接触柱端面的4只螺钉。熔断体的两端分别插入手柄中的接触柱内并用紧定螺钉固定,插入支持件。Thefuse-linkisfixedinthefuse-carrier,asshowninFig.5.Solder-coveredoffuse-linkmustshunthefourboltsof.Eachsideofthefuse-linkshouldbeinsertedintotheconnecting-cartridgeandfixedbyabolttightlythenputitintothefuse-mount.3.熔断器的安装Fuse在底座上端放好O形密封圈,见安装示意图6所示。把安装好的熔断件插入底座,最后用专用拧紧扳手旋紧盖。ThesealwasherofOspeciesisfixedonthefuse-mount,asshowninFig.6.Thefuse-linkisinsertedintofuse-mount.Useawrenchtotightencasing.◆概述General□ZGR5(XRNT4)-12变压器保护用高压限流后备熔断器(以下简称熔断器)适用于交流50Hz,额定电压12KV,额定电流至16A的户内电力系统中,作为电力变压器的过载和短路保护。□ZGR5(XRNT4)-12H.V.current-limitingBack-upfuseforprotectionoftransformer(here-underfuse)isavailableforH.V.indoorelectricsystem,withratedvoltage12KV,ratedcurrentupto16A,50Hza.c..Itisusedforprotectingfromoverloadandshort-circuitforpowertransformer.◆标准Standard符合GB15166.2交流高压熔断器限流式熔断器AccordwithGB15166.2Alternating-currenthigh-voltagefusesCurrent-limitingfuse◆熔断器的结构Construction熔断器是由熔断件、手柄和支持件、密封圈、防护罩等组成。熔断件的两端分别插入手柄中的接触柱内并用紧定螺钉固定,插入支持件。加上密封圈,拧紧防护罩。熔断器具有防油、防水功能。Thefuseconsistofafuse-link,afuse-carrierandafuse-mountsealwashershieldetc.Eachsideofthefuse-linkshouldbeinsertedintotheconnecting-cartridgeandfixedbyabolttightlythenputitintothefuse-mount.Addasealwasherandtightenaprotectingcover.Itisaoil-proofandwater-prooffuse.◆基本参数Basicparameters额定电压KVRatedvoltage熔断器额定电流ARatedcurrentofthefuse1216熔断件额定电流ARatedcurrentofthefuse-link额定短路开断电流KARatedshortcircuitbreakingcapacitycurrent6.3、8、10、12.5、1616雷电冲击耐值(峰值)KALightningimpulsevoltage(Max)使用环境Operatingcondition对地断口空气、油中Airoil7595◆外型及安装尺寸InstallationDimensios熔断件的外形尺寸图1熔断件的外形尺寸见图1,熔断器的外形尺寸及安装尺寸见图2Dimensionsofthefuse-linkareshowninFig.1,andDimensionsoftheoverallandinstallationofafuseseeFig.2.图4底座的安装示意图图5图6◆熔断器使用注意事项Notice熔断器的时间-电流特性TheTimecurrentCharacteristicOfTheFuse1、当熔断器正常使用于变压器绝缘油中,周围油的温度上限不允许超过100℃。当周围油度高于40℃时,熔断器须降容。2、当熔断件熔断后,必须换上型号和尺码等参数相同的新熔断件,切勿以其它器件代替。在更换熔断件时,发现熔断件的熔管发黄或者熔断器绝缘筒内有气雾泄出,属于正常现象。3、对三相安装的熔断器,除非已肯定仅其中一只承担过故障电流,否则即使一只熔断器动作,其它两只均应更换。4、用户在更换新熔断件时,应同时更换起防水作用的O形密封圈。1、Theupperlimitofoiltemperaturecannotexceed100whenthefuseisnormallyusedinthedielectricoiloftransformer.Thefuse’scapacitymustbetakenfromiftheoiltemperatureexceeds40.2、Ifdamaged,thetypeandmaintechnicaldataofthereplacedfuse-linkmustbesamecompletely,nottoreplacebytheisnormalphenomenaiffuse-cartridgebecomesyellowordielectriccanisterventsinhalators.3、Thefusesinthreephase,oneoffusesisdamaged,theothermustbereplaced.unlessoneof廿1emhasbeenknowntobebreakingoperation.4、ThesealwasherofOspeciesofwaterproofmustbereplacedwhenthenewfuse-linkisreplaced.熔断器的时间-电流特性曲线上海智广熔断器有限公司专业生产高压熔断器,低压熔断器,高压限流熔断器,熔丝,高压熔丝高压熔断器:http:///gyrdq/ml低压熔断器:http:///dyrdq/ml)