德国Doble Lemke GmbH 放电装置 分析仪
类型排气分析仪检测误差0.1(%)工作温度100(℃)电压230(V)尺寸100(mm)品牌DobleLemkeGmbH型号DobleLemkeGmbH希而科贸易(上海)有限公司-德国Silkroad24GmbH中国***希而科贸易(上海)有限公司-德国Silkroad24GmbH中国***联系人:张敏(业务部销售经理)TEL:13585754584021-58375543-829FAX:021-61179684EMAIL:zm@***:1784691511MSN:zhangsir_goal@希而科优势代理德国DobleLemkeGmbH放电装置分析仪产品系列:PARTIALDISCHARGEPDS100ThePartialDischargeSurveyorPDS100providescompletesubstationPDsurveycapabilites.BysimplywalkingaroundtheHVapparatus,sourcesofpartialdischargesandexternalintereferencecanbedetectedandidentified.RoutineRFIsurveyingwillassistinlocatingpartialdischargeactivitywhiletheapparatusisstillinservice.Readmore...PD***ARTOurdigital,highlyadvancedpartialdischargemeasuringanddiagnosticdevicePD***ARTischaracterizedbyitsuniquecompactnessanditsprecisemeasurements.Readmore...LDS-6andLDS-6/UHFForover10years,thedigitalandportablePDmeasuringanddiagnosisdeviceLDS-6accompanythousandsofusersaroundtheworld.Withthehelpofthevariousplug-in's,theLDS-6allowsalsonarrow-band,RIVandUHFpartialdischargemeasurements,besidesconventionalPDmeasurements.ReadmoreLDS-6...ReadmoreLDS-6/UHF...LDP-5TheportableDifferentialLEMKEPROBELDP-5detectsandlocatesdangerouspartialdischargesinHVequipment.Duetothelight-weightc***truction,theLemkeprobeLDP-5canbeusedforbothon-siteinspecti***andmeasurementsinthelaboratory.Readmore...LDA-6TheLDA-6isusedforacousticlocalizationofpartialdischargesinsidepowertransformers.Theacoustic,multi-channeldetectionofpartialdischargescanalsobecombinedwithelectricalpartialdischargemeasurements.Readmore...LDA-5/SThePDdetectorLDA-5/SisusedfordetectionoftheultrasonicsoundsignalofPDeventsataresonancefrequencyof40kHz.Dependingonthetypeofultrasoundreceiver,eitherpartialdischargesinair(corona)orinHVequipmentcanberecognized,asforinstanceincablesystems,powertransformersandswitchgears(incl.GIS).Readmore...PARTIALDISCHARGEMONITORINGPD-GUARDThePDmonitoringsystemPD-GUARDisespeciallydevelopedforcontinouspartialdischargemonitoringofhighvoltageequipment,suchasgenerators,motors,powertransformersintheconventionalrangeoffrequency.Readmore...PD-GUARD/UHFFortheimplementationofpermantUHFpartialdischargemeasurements,thePDmonitoringsystemPD-GUARD/UHFisused.ThePD-GUARD/UHFisespeciallydesignedforcontinousPDmonitoringongas-insulatedswitchgears(GIS)andcablesystems.ThedecouplingofthepartialdischargeswillbedoneintheUHFfrequencyrange.Readmore...DISSIPATION&POWERFACTORTD-***ARTThedigitaldissipationandcapacitancemeasuringsystemTD-***ARTisahigh-precise,modularacqusitionandanalysissystemformeasruingthecurrentandotherkeycharacteristicsofelectricalequipment,includingdissipation&powerfactoraswellascapacitance.Readmore...PROTECTIONDIAGNOSTICSF6150TheF6150PowerSystemSimulatorusesstate-of-the-artdigitalsignalprocessingandpoweramplifierstodeliverahighpower,lightweightinstrumentforallprotectiontestingapplicati***.Readmore...CONTINUOUSONLINEDIAGNOSTICSDobleIntelligentDiagnosticDevice(IDD)Application:Transformers/CircuitBreakersIntelligentDiagnosticDevices(IDDs),afamilyofcontinuousonlinediagnosticdevicesforpowersystemapparatus,aredesignedtodetectincipientproblemswithbushings/CTs,transformers,andcircuitbreakers.Nowyoucansafelymanageprogressiveproblemsandefficientlyschedulecorrectiveaction.TherearethreetypesofIDDinstruments:Moisture,Bushings,andDissolvedGasAnalysisReadmore...DobleLCM500TheDobleLCM500isawirelesssystemforconditionmonitoringofyourmetaloxidesurgearresters(MOSAs).TheLeakageCurrentMonitor(LCM)systemmeasurestheresistivecomponentofcontinuousleakagecurrentwhiletheMOSAisinserviceandwillinstantlygivevaluabledatafortheasses***entofthearrestercondition.Readmore...DobleDOMINOAccuratemoistureandtemperaturedataisnecessarytodeterminetheconditionofelectricalapparatusoritsinsulatingliquid.However,thedatabyitselfmaynotalwaysbesufficienttoidentifypotentialproblems,especiallyintransformersystems.Dobledevelopedoneofthefirstanalyticaltechniquesformeasuringdissolvedwaterinoilandthefirstonlinemoisturemonitor:DOMINO.Readmore...CIRCUITBREAKERDIAGNOSTICSDobleTDR900TheTDR900isastate-of-the-artCircuitBreakerTestSystemengineeredtotestalltypesofcircuitbreakers.TheTDR900providesefficientandaccurateperformancemeasurementsforcircuitbreakers.Itperformstimingfuncti***foruptofourbreaksperphasewithmotionmeasurements.Readmore...DobleTDR100TheTDR100CircuitBreakerTestSystemisasimple,effectivewaytoassesstheconditionofcircuitbreakersandswitchingdevices.TheTDR100isacompactunitthatprovidesquickandreliableresults.Readmore...SURGEARRESTERSMONITORINGDobleLCM500TheDobleLCM500isawirelesssystemforconditionmonitoringofyourmetaloxidesurgearresters(MOSAs).TheLeakageCurrentMonitor(LCM)systemmeasurestheresistivecomponentofcontinuousleakagecurrentwhiletheMOSAisinserviceandwillinstantlygivevaluabledatafortheasses***entofthearrestercondition.Readmore...SWEEPFREQUENCYRESP***EANALYSISDOBLEM5400TheDobleM5400SweepFrequencyResp***eAnalyzerisusedforreliablecoreandwindingdiagnosisofyourpowertransformer.UsetheM5400toensuretransformerperformance,reducemaintenancecostsandincreaseservicelife.Readmore...DOBLEM5300TheM5300SweepFrequencyResp***eAnalyzerperformsthesamefuncti***astheM5400,buttheM5300hasabuilt-inPCandvisualdisplayandcomeswithaLaptopkeyboard.Readmore...INSULATIONANALYSISM4100Diagnostictestsystemforpowerapparatusconditionasses***ent.M2HMCMDiagnostictestsystemforpowerapparatusconditionasses***ent.OIL/MATERIALSANALYSISDOMINOMoistureSensors-Permanent-MountSensorsTheDOMINOsensormeasuresmoistureinoilintermsofppmandrelativesaturation(RS),aswellastemperature.Itprovidescontinuous,reliablemeasurementofthewatercontentofelectricalinsulatingliquidsandothertypesofoils.Determiningthemoistureininsulatingliquidsisanessentialpartofanycomprehensivemaintenanceordiagnosticprogram.Readmore...DOMINOUltimateSamplingSystem(USS)DOMINOUSSisaportablesystemc***istingofeitheramoisture-in-oilsensororamoisture-in-gas(dewpoint)sensor,orboth.Shippedinahandycarryingcase,itprovidesafast,convenientwaytotakehigh-qualitysamples.Readmore...DOBLEMaterialsLaboratoryTheDobleLaboratoryisfullyequippedtoperformawidevarietyoftestsoninsulatingmaterials,withmorethanfiftytestsofferedonaroutinebasis.TheDobleLaboratorycanprovideanswersandsoluti***toyourproblems,basedonqualitydatafromawidescopeoftestingcapabilitiesandrichexperienceinapparatusdiagnostics.HVTESTSYSTEMSAutomaticHVControlUnitThiscontrolUnitisdesignedforfully-automaticcontrolofhighvoltagetestsystems.Followingapplicationareascanbeserved:•fixed-frequencyACtesttransformersystem•variable-frequencyACresonanttestsystemReadmore...MANUALHVCONTROLUNITDoble-LemkeofferstwokindsofmanualHVcontrolsforyourHVtestsystem:ManualControl"LDcontrol"forHVTestSystemswithRegulatingTransformer(fixedfrequency50/60Hz)Readmore...ManualControl"LDcontrol"forHVTestSystemswithResonantTestSet(variablefrequency)Readmore...RITHERM/SAWTECHNOLOGYTEMPERATUREMEASUREMENTTheSAWsensorsallowapotential-freedeterminationofactualtemperaturevaluesofswitchgear,overheadtran***issionlinesandotherHVapparatus.LOADOPTIMIZATIONONOVERHEADTRAN***ISSIONLINESRITHERM®nowmakesexact,continuousandlow-costmonitoringofoverheadtran***issionlinespossibleforthefirsttime.)
希而科贸易(上海)有限公司
姓名: 康经理 先生
手机: 18721676936
业务 QQ: 2916018547
公司地址: 上海市奉贤区奉金路469号4幢3层2435室
电话: 021-57559659
传真: 021-57559659