德国THERMOCOAX GmbH加热器 温度传感器 变送器
型号THERMOCOAX规格THERMOCOAX品牌THERMOCOAX材质THERMOCOAX名称THERMOCOAX适用范围THERMOCOAX希而科贸易(上海)有限公司-Silkroad24GmbH中国办事处联系人:张敏(业务部销售经理)TEL:13585754584021-58375543-829FAX:021-61179684EMAIL:zm@QQ:1784691511MSN:zhangsir_goal@希而科优势代理德国THERMOCOAXGmbH加热器产品系列:THERMOCOAXheatingelementswithcoldendsTHERMOCOAXImmersionheaterAbettersolutiontokeepthealuminiumhotTHERMOCOAXHeatingelementsResistanceheatingisoneofthefirstapplicationsofelectricity..Inthecourseofacentury,thousandsofheatingproblemshavebeensolvedrangingfrommegawattsdowntoafewwatts,orless.Thefundamentalsarealwaysthesame,therequirementsandsolutionswidelydifferent.Betweenalargefurnaceconstructedasanindividualunitandadomesticheaterproducedinlargequantities,thereexistanumberofcaseswhereno“ready-made”solutionisavailable.Forsuchcases,THERMOCOAXoftenpresentsasuitableanswerto:Heatingfromthecryogenictemperaturesupto>1000°C.Heatdissipationeitherveryloworveryhighpower(fromfewwattstoseveraltensofkilowatts).Foruseinair,undervacuumorhighpressureandinanycorrosiveenvironmentcompatiblewiththesheathmaterial.Inapplicationsrequiringhighreliabilitycomponents.EasyfittingElectricalscreeningTHERMOCOAXheaterscanbeattacheddirectlytometalpartsTightbendingradiusOnly3timestheouterdiameterSmalldimensionsTheheatcanbegeneratedexactlywhereitisrequiredthuspowerlossesarereducedaswellaspowerconsumptionExcellentheatexchangeTheheatercanbebrazedontoanymetalpieceMoreinformationaboutHeatingElements:DownloaddatasheetsSinglecoreheatingelementsStandardrangeWithoutcoldendsWithcoldendsWithtruecoldendsSelf-regulatedWithcoiledcoreTwincoreheatingelementsWithoutcoldendImmersionheaterCeramicprotectedimmersionheaterOthersConnectorsAccessoriesTemperaturesensorsThemeasurementoftemperatureisaveryimportantelementinmanypartsofresearchandindustry.Awell-knownandprovenmethodintemperaturemeasurementistheuseofthermocouples.Accurateandfastmeasurements,easymounting,simpleutilisationandinterchangeabilityaswellaslow-costproductionarethereasonsforthewidespreadapplicationsofthethermocouples.Theyareresistanttoheatandpressureandrelativelyinsensitivetoparasites.Specifictechnicalrequirementslikewithinnuclearreactors,inspaceresearchorinmedicalfieldsledtothedevelopmentofsheathedthermocouplesofsmalldimensions,highinsulationresistanceandhighresistancetoaggressivemedia.Allthisisbeingfulfilledbyminiaturesheathedthermocouples.THERMOCOAXoffersthebestpossiblesolutionstotemperaturemeasurement.Manysensorsarestandardoff-the-shelfdesigns,butmanyothersareespeciallydesignedandmanufacturedtocustomerrequirements,withinawiderangeofspecificationsorevendevelopedinpartnershipwithourcustomers.Smalloveralldimensionsandhighflexibilityenabletemperaturemeasurementinlocationswithpooraccessibility.Highmechanicalstrength.Protectionofthethermoelectricwiresagainstoxidation,corrosionandchemicalpollution.AccuratemeasurementShortresponsetime:asanexample,theintrinsicresponsetimeofa0.25ODmmTHERMOCOAXthermocoupleis7ms,theactualresponseinhighvelocityairisthen0.1s.Thisveryfastresponsetimeallowsmeasurementofveryshorttemperaturevariations.EasyfittingThecontinuousmetallicsheathensuresamechanicalandchemicalprotectionofthecoupleandTHERMOCOAXthermocouplescanbeattacheddirectlytometalpartsTightbendingradiusOnly3timestheouterdiameterSmalldimensionsDownto0.25mmOD,theTHERMOCOAXthermocouplescanbeinsertedinanytinyequipmentMoreinformationaboutThermocouples:DownloaddatasheetTypeK:Ni-Cr(+)/Ni-Al(-)TypeN:NiCrSi(+)/NiSi(-)TypeJ:Iron(+)-/Constantan®(-)TypeE:NiCr(+)/Constantan®(-)TypeT:Copper(+)/Constantan®(-)HightemperaturethermocouplesTypeS:Pt10%Rh(+)/Pt(-)TypeR:Pt30%Rh(+)/Pt(-)TypeB:Pt30%Rh(+)/PtRh(-)Thetungsten-rheniumthermocouplesTypeC(rigidorflexible):Tungsten-rhenium5%Re(+)-Tungsten-rhenium26%Re(-)OtherthermocouplesStandardoff-the-shelfthermocouplerangeStick-onthermocouplesATEXTemperaturesensorsThethermocoupesandRTDsrangecoversExZones0to2and20to22.Zones0and1:intrinsicsafety-marking"EExia"inaccordancewithEN50020.Zone2:EnergyLimitedCircuit-marking"EExnL"inaccordancewithen50021Thesametechnicalpropertiesasforthestandardthermocouplerangeapplyforthesesensors.OnlythefittingandsomeusedcomponentsareadaptedtotheATEXrequirements.TechnicaldetailsareavailableinthedocumentSE900R009ATEXheatingTheRelevantProtectionPrincipleforTHERMOCOAXheatersare:Zone1and2:flameproofenclosuremarking"EEXd"inaccordancewithEN50018.Theheaterspropertiesarethoseofthestandardrange.Detailsaregivenintheheatingproductrange.ATEXQuestionnaireAsforanyproductintendedforpotentiallyexplosiveatmospheres,adedicatedquestionnairehastobefilledoutpriororderexecution.Pleasedownloadtheform:ATEXquestionnaire.pdfandfillitoutdirectly.Oncecompleted,printit,addyourcompanystampandsignatureandpostittooursalesdepartment.MineralInsulatedSignalTransmissionCablesThankstotheirexceptionalproperties,THERMOCOAXcablescan:Beusedinthemostaggressivemedia:highpressure,vacuum,corrosiveliquidsorgases,vibrations,nuclearWithstandveryhighinsulationresistance:overto1013OhmsResisttoveryhightemperaturesworkupto1200°CCarryrelativelyhighcurrentsaswellasverylowsignalsathighfrequencyBeweldedorbrazedontoanypieceortopassthroughawall.DedicatedapplicationsforNuclearenergyAeronautics,DefenceandSpaceCryogenicprocessesChemistryandpetrochemistryVacuumtechnologyHydraulicsystemsSteamandgasturbinesRoboticsMoreinformationaboutMIcables:DownloaddatasheetSingleconductorMulticonductorsLowcapacitanceforhyperfrequencysignalsCoaxialandtriaxialforhighfrequencyTheCOFRACcalibrationTHERMOCOAXmetrologydepartmentisaccreditedbytheCOFRACCalibrationSectionundertheregistrationnumber2.1384referringtocalibrationatfixedpointsofthethermoelectricalcouples.Oven2000°CThermalcyclingControlsandtestsSystematiccontrolsguaranteethequalityoftheTHERMOCOAXproducts:X-rayofthehotjunction,sheathintegritytest,metallographictestonsample,calibrationwithappropriatethermaltreatmentdimensionalelectromotiveforces(ITS90).certificateofcomplianceonrequestSpecificsensorsHightemperatureCapacitiveSensorsTURBOCOAXTheTURBOCOAXcapacitivesensorsweredevelopedtomeasuretheclearancebetweenthetipoftheturbinebladesandthecasingofturboengines.Non-contactbladetipclearancemeasurementNocoolingsystemrequiredSmalldimensionsWithstandtemperaturesupto1,400°COtherapplications:Speedand/orcountingmeasurements,Levelorthickness,vibrationsNEGACOAX®overheatingandfiredetectorsThelinearsensorsNEGACOAX,todetectoverheatingandfires,areallconstructedemployingthemineralinsulatedcabletechnology.Applications:ChemicalandpetrochemicalindustriestemperaturecontrolandsurveyofprocessesAerospaceindustriesjetengineandstructureSpaceindustriesrocketthrust,detectionofleakinghotgasandanyotherindustrywherethesafetyaspectisakeyfactor.TrafficcontrolwithVIBRACOAX®Weigh-InMotionsensorsWhenusedwithappropriateinstrumentation,VIBRACOAXcanprovideawiderangeofinformationincluding:Weigh-in-Motion(WIM)VehicleclassificationAxlecountinganddistancesbetweenaxlesGrossvehiculeandloaddistributionSpeedmeasurementTrafficvolumeTHERMOCOAXmanufacturestheVIBRACOAXpiezoelectricaxlesensorsincethemid1970s.Thesensorisusedindatacollectionapplications.Thesensorishighlyaccurateandreliablewithtremendouslongevityandgenerallyoutlivesthepavementinwhichitisinstalled.NEUTROCOAX®neutrondetectorsbySPNDTheNEUTROCOAXSPNDisaneutronabsorbermaterialcalledemitter,insulatedfromthesheathorcollectorbyaluminaormagnesiainsulatorinacoaxialgeometry.TheSPNDisconnectedtoanamplifierbyasingleleadortwinleadTHERMOCOAXcoaxialcablecapableofcorrectingthespuriouscurrentduetotheirradiationofthecable.TheTHERMOCOAXSPNDcanbeusedinalltypesofreactorsforin-coremeasurementofthermalneutronfluxfor:goodknowledgeoftheneutronfluxdistributionmonitoringtheenergyconversioninthereactorsabettercontrolofthesafetycriteria.Applications:accuratemonitoringofthermalneutronflux,inirradiationexperimentsorinstrumentationDownloadbrochure:TURBOCOAXDownloadbrochure:NEGACOAXDownloadbrochure:VIBRACOAXDownloadbrochure:NEUTROCOAX)