(九成新)ZVR 4G网络分析仪罗德与施瓦茨10Hz4GHz还可以回收
价格:6000.00
ZVR4G网络分析仪罗德与施瓦茨10Hz4GHz的详细介绍长期|出租|回收|维修|销售|收购:网络分析仪,频谱分析仪,LCR电桥,无线电综合测试仪,信号源,色差仪,色彩分析仪,变压器测试仪,示波器,音频分析仪,视频分析仪,万用表,蓝牙测试仪,电声测试仪,电子负载、频率计、GPIB卡,PCI-GPIB卡、GPIB-USB-B、功率计线材测试机等仪器电话:13332607146(冉经理)0769-28311616***:632292909邮箱:ranlc75@Rohde&SchwarzZVR4G网络分析仪罗德与施瓦茨10Hz4GHzR&SZVR4G矢量网络分析仪|R&S|9KHz至4GHz厂商名称:德国罗德与施瓦茨Rohde&SchwarzR&S特点·9(10)kHz~4GHz频率范围·高测量速度(<125μs/测量点)·低固有噪声(-130dB)·宽动态范围(>130dB)·高频率分辨率(10μHz)·校准时间短(<20s)·有源彩色LCD(26cm)技术指标·Dataonlyfor50Ωtestsets.For75ΩtestsetsandfurtherdetailspleaserefertodatasheetPD757.1802.23.Unlessotherwisestated,specificati***applytotestportsPORT1andPORT2,anominalsourcepowerof-10dBmatthetestportandanIFbandwidth≤10kHz·Thearrowmarksimportantdata.·Frequencyrange,measurementspeed,dynamicrange·Frequencyrange·WithoutExternalMeasurementsoption·ZVRL,ZVRE,ZVR·withpassivetestset50Ωor75Ω|9kHzto4Ghz·withactivetestset50Ωor75Ω|300kHzto4GHz·ZVRL,ZVRE,ZVR|10Hzto4Ghz·Relativefrequencydeviation|<2*10^-6+1*10^-6/a·Resolution|10μHz·Measurementspeed(above2Mhz)·Numberofpoints|1to2001(selectable)·Measurementtimeperpoint|IFbandwidth(IFBW)3kHz10kHz26kHzwithsystemerrorcorrection<1.50μs<460μs<330μsnormalized<530μs<230μs<190μsFastModewithsystemerrorcorrection--<240μsnormalized--<125μs·Dynamicrange(withoutsystemerrorcorrection)·ZVRL,ZVRE,ZVR·(modelsZVRLandZVRE:atIFbandwidth10Hzvaluesarereducedby5dB)IFbandwidthWithpassivetestset50Ω10Hz3kHz10kHz20kHzto20MHz>65dB,typ.>110dB--200kHzto20MHz>110dB>90dB>85dB20MHzto3Ghz>120dB>100dB>95dB3Ghzto4Ghz>110dB>90dB>85dBWithactivetestset50Ω300kHzto1Mhz>107dB>87dB>82dB1MHzto20MHz>110dB>90dB>85dB20MHzto3Ghz>120dB>100dB>95dB3Ghzto4Ghz>110dB>90dB>85dBWithExternalMeasurementsoption50Hzto200kHz>75dB--200kHzto20MHz>110dB>95dB>90dB20MHzto1Ghz>130dB>110dB>105dB1Ghzto3Ghz>120dB>100dB>95dB3Ghzto4Ghz>110dB>95dB>90dB·ZVCE,ZVC·(modeZVCE:atIFbandwidth10Hzvaluesarereducedby5dB)·Withactivetestset50Ω20kHzto200kHz>60dB,--200kHzto20MHz>100dB>80dB>75dB20Mhzto3Ghz>120dB>100dB>95dB3Ghzto4Ghz>110dB>90dB>85dB4Ghzto6Ghz>105dB>85dB>80dB6Ghzto8Ghz>100dB>80dB>75dBWithExternal/Measurementsoption20kHzto200kHz>75dB--200kHzto20Mhz>110dB>95dB>90dB20MHzto1GHz>130dB>110dB>105dB1Ghzto3Ghz>120dB>100dB>95dB3Ghzto4Ghz>110dB>95dB>90dB4GHzto6GHz>105dB>90dB>85dB6Ghzto8GHz>100dB>85dB>80dBStabilityofmeasurementtraceperdegreetemperaturevariationZVRL,ZVRE,ZVR<0.05dBor0.4°Measurementbandwidth(IFbandwidthIFBW)1Hzto10kHz(half-decadesteps)and26kHz(full)·Measurementaccuracy·Thefollowingdataarevalidbetween20℃and30℃providedtheinstrumenthasreachedthermalequilibrium(about1hafterswitch-on)andthetempera-turehasnotvariedbymorethan1degreeaftercalibration.·ZVREandZVR(bidirectionalnetworkanalyzers)·Accuracyoftran***issionmeasurementsafterfulltwo-partsystemerrorcor-rection(TO***)·Specificait***arebasedonamatchedDUTandrefertoanominalsourcepowerof-10dBmatthetestport.·Withtestset50Ω·300kHzto4Ghz·atIFbandwidth10Hz·for+10dBto+3dB|<1dBor6°·for+3dBto-5dB|<0.2dBor1°·for-5dBto-60dB(passive)|<0.05dBor0.4°·for-5dBto-60dB(active)|0.2dBor1°·for+3dBto-40dB|typ.<0.025dB·for-60dBto-70dB|<0.2dBor1°·for-70dBto-80dB(ZVRE)|<1dBor6°·for-70dBto-85dB(ZVR)|<1dBor6°·Accuracyofreflectionmeasurements·aftersystemerrorcorrection(TO***orfullone-port)·Specificait***arebasedonanisolationgDUTandrefertoanominalsourcepowerof-10dBmatthetestport.·Withtestset50Ω·Itisassumedthatthereturnlossofthematchusedforcalibrationis>46dB(effectivesystemdata:directivityDeff>46dB,testportmatchSeff>30dB).·20kHzto4Ghz(passivetestset),·300kHzto4GHz(activetestset)·for+10dBto+3dB|<1dBor6°·for+3dBto-15dB|<0.4dB+0.04dB/Ghz,<3°+0.4°/Ghz·for-15dBto-25dB|<1dBor6°·for-25dBto-35dB|<3dBor20°·ZVCEandZVC·Accuracyoftran***issionmeasurements·afterfulltwo-partsystemerrorcorrection(TO***)·Specificati***arebasedonamatchedDUTandrefertoanominalsourcepowerof-20dBmatthetestport.·10MHzto4Ghz·atIFbandwidth10Hz·for+10dBto+3dB|<1dBor6°·for+3dBto-50dB|<0.2dBor1°·for+3dBto-40dB|typ.<0.025dB·for-50dBto-60dB|<0.5dBor4°·for-60dBto-70dB(ZVCE)|<1dBor6°·for-60dBto-75dB(ZVC)|<1dBor6°·4Ghzto8Ghz·atIFbandwidth10Hz·for+10dBto+3dB|<1dBor6°·for+3dBto-45dB|<0.2dBor2°·for+3dBto-40dB|typ.<0.025dB·for-45dBto-55dB(ZVCE)|<1dBor6°·for-45dBto-60dB(ZVC)|<1dBor6°·Accuracyofreflectionmeasurements·aftersystemerrorcorrection(TO***orfullone-port)·Specificati***arebasedonanisolaitngDUTandrefertoanominalsourcepowerof-20dBmatthetestport.·Itisassumedthatthereturnlossofthematchusedforcalibrationis>40dB(effectivesystemdata:directivityDeff>40dB,testportmatchSeff>30dB).·20kHzto8Ghz·for+10dBto+3dB|<1dBor6°·for+3dBto-·10dB|<0.4dB+0.04dB/GHz,<3°_0.4°/Ghz·for=\-10dBto-20dB|<1dBor6°·for-20dBto-30dB|<3dBor20°·ZVRL(unidirectionalnetworkanalyzer)·Accuracyoftran***issionmeasurements·aftersystemerrorcorrection(one-pathtwo-port)·Specificati***arebasedonamatchedDUTandrefertoanominalsourcepowerof-10dBmatthetestport.·Withtestset50Ω·Itisassumedthatthereturnlossofthematchusedforcalibrationis>46dB(effectivesystemdata:directivityDeff>46dB,testportmatchSeff>30dB).·20khzto4Ghz·for+10dBto+3dB|<1dBor6°·for+3dBto-15dB?|<0.4dB+0.04dB/Ghz,<3°+0.4°/Ghz·for-15dBto-25dB|<2dBor6°·for-25dBto-35dB|<3dBor20°·Effectivesystemcharacteristics(above200kHz)·Thesedataarevalidbetween20℃and30℃providedtheinstrumenthasreachedthermalequilibrium(about1hafterswithc-on)andthetemperaturevariati***isnotmorethan1degreeaftercalibration.ZVRE,ZVR,ZVCE,ZVC(bidirectionalnetworkanalyzers)·Afterfulltwo-portsystemerrorcorrection(TO***)·ZVRL·Aftersystemerrorcorrction(one-pathtwo-port)·Directivity|>46dB^1)·Sourcemathch(PORT1)|>30dB·Loadmatch(PORT2)|>18dB·Tran***issiontracking|<0.2dB·Reflectiontracking|<0.06dB·Outputpower·Powerrange(withoutopti***)·ZVRL,ZVRE,ZVRwithtestset50Ω|-25dBmto0dBm·ZVRL,ZVRE,ZVRwithtestset75Ω|-27dBmto-6dBm·ZVCE,ZVC·20kHzto6GHz|-25dBmto0dBm·6GHzto8GHz|-25dBmto-3dBm·Deviation(at-10dBm)·Thesedataarevalidbetween20℃and30℃·upto2Mhz|<1dB·above2Mhz|<0.5dB·Linearity(referredto-10dBm)·0dBmto-25dBm(upto20kHz)|<0.8dB·0dBmto-15dBm(above20kHz)|<0.4dB15dBmto-25dBm|<0.6dB·Resolution|0.1dB·Spectralpurity·Harmonics|ZVRL,ZVRE,ZVR|ZVCE,ZVC40kHzto400MHz<-25dBc<-25dBcabove400MHz<-30dBc<-25dBcAt-10dBmsourcepowerupto600MHz<-35dBc<-35dBcabove600MHz<-40dBc<-35dBcSpurious<-40dBcSSBphasenoise1Hzbandwidth,10kHzfromcarrierupto10MHz<-110dBc10MHzto150MHz<-100dBc150MHzto1Ghz<-90dBcabove1Ghz<-90dBc+20.log(f/GHz)(<-78dBcat4Ghz),<-72dBcat8Ghz)ResidualFMRMSweighfingfrom10Hzto3kHzupto10MHz<1Hz150MHzto1Ghz<5Hz1Ghzto2Ghz<10Hz2Ghzto4Ghz<20Hzabove4Ghz<40HzInputlevelMaximumnominalinputlevelReceiverstepattenuator0dB≥30dBWithoutopti***0dBm-WithreceiverStepAttenuatoroption0dBm+27dBmDamagelevelWithoutopti***+27dBm-WithReceiverStepAttenuatoroption+27dBm+30dBmDamageDCcurrent/voltageWithpassivetestset(internalDCshortRin<0.1Ω)0.5AWithactivetestset0.5Aor30VRMSnoiselevel(50Ω,withoutopti***)With75Ωmodelsthenoiselevelishigherby6dBFrequencyrangeIFbandwidthNoiselevel9khzto50khz1kHz<-75dBm50kHzto200khz3kHz<-70dBm200khzto20Mhz3khz<-90dBm20MHzto3Ghz3Ghz<-100dBm3Ghzto4Ghz3Ghz<-90dBm4Ghzto8Ghz3kHz<-80dBm)
东莞国仪电子仪器有限公司
业务 QQ: 632292909